Rheem Error Code 1 blink: Soft lockout (failed ignition) (Furnace)
Rheem error code 1 blink on a furnace means: Soft lockout (failed ignition). It is also called Rheem diagnostic code 1 blink.
Homeowner? What Rheem code 1 blink means for you
Call a technician Your furnace is reporting: Soft lockout (failed ignition). The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code 1 blink mean?
Green STATUS LED blinks once: the control has given up after 4 ignition attempts and is in a 1-hour soft lockout; it ignores the heat call (W) until reset. The chart says to kill power 30 s to reset; the Sequence of Operation says 5 s (or cycle W off/on) and also 5-10 s at the thermostat or disconnect - see notes.
Applies to: Rheem (-)GRC upflow and (-)GTC downflow/horizontal 90 Plus condensing gas furnaces (UT Electronic Controls 1012-925 / 1028-928 and Invensys ICC-H1MC7-01 IFC); Rheem 90RJ and 90TJ 90 Plus condensing gas furnaces (UT Electronic Controls 1012-925 or Invensys ICC-H1MC7-01 IFC, hot surface ignition)
Common causes of Rheem code 1 blink
- No or low gas supply / wrong manifold pressure
- Igniter not heating (HSI open, cracked, mis-placed) or spark electrode not sparking (DSI)
- Weak or no flame signal - dirty flame sensor rod, poor ground, L1/Neutral reversed
A technician checks these and 2 other possible causes on site before replacing any part.
Rheem models that use code 1 blink
Show all 23 models
90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS
Other Rheem Furnace codes
All Rheem Furnace error codes →
Rheem code 1 blink: homeowner questions
What does Rheem code 1 blink mean?
Soft lockout (failed ignition). Green STATUS LED blinks once: the control has given up after 4 ignition attempts and is in a 1-hour soft lockout; it ignores the heat call (W) until reset. The chart says to kill power 30 s to reset; the Sequence of Operation says 5 s (or…
Is it safe to keep using my furnace with code 1 blink?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rheem code 1 blink myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code 1 blink comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code 1 blink near me?
Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Rheem (-)GRC/(-)GTC Installation Instructions 92-24161-88-00, Figure 56 IFC Troubleshooting Guide, p.54 (printed); Rheem 90RJ/90TJ Installation Instructions 92-24161-32-08, Figure 53 IFC Troubleshooting Guide, p.54 (printed p.53). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.