Rheem Error Code 23: HALC limit open (HALC LIMIT OPEN) (Furnace)
Rheem error code 23 on a furnace means: HALC limit open (HALC LIMIT OPEN). It is also called Rheem diagnostic code 23.
Homeowner? What Rheem code 23 means for you
Call a technician Your furnace is reporting: HALC limit open (HALC LIMIT OPEN). The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code 23 mean?
Heat Assisted Limit Control open. HALC is only on downflow/horizontal models; when it opens it often means the main blower stopped turning unexpectedly. Thermostat also shows Call For Service / CHECK FURNACE to the homeowner.
Applies to: RGPE/RGLE 2-stage 80+
Common causes of Rheem code 23
- Blower stopped or failed (60/61/68)
- Airflow restriction
- Loose HALC wiring
Rheem models that use code 23
96MDV115D50ARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Other Rheem Furnace codes
All Rheem Furnace error codes →
Rheem code 23: homeowner questions
What does Rheem code 23 mean?
HALC limit open (HALC LIMIT OPEN). Heat Assisted Limit Control open. HALC is only on downflow/horizontal models; when it opens it often means the main blower stopped turning unexpectedly. Thermostat also shows Call For Service / CHECK FURNACE to the homeowner.
Is it safe to keep using my furnace with code 23?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rheem code 23 myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code 23 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code 23 near me?
Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: RGPE/RGLE: Table 16 p.49 / Table 20; user menus p.52. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.