Rheem Error Code Defrost test (SW2): Forced defrost test (Heat Pump)
Rheem error code Defrost test (SW2) on a heat pump means: Forced defrost test. It is also called Rheem diagnostic code Defrost test (SW2).
Homeowner? What Rheem code Defrost test (SW2) means for you
Usually minor Your heat pump is reporting: Forced defrost test. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code Defrost test (SW2) mean?
With the unit running in heat-pump mode, pressing the SW2 pushbutton forces a defrost that runs until the termination temperature is reached or 14 minutes pass. Pressing SW2 again ends the test. If the unit goes into and out of defrost, the control is working.
Applies to: Rheem/Ruud PRL-JEC heat pumps with Comfort Control2 ICC
Rheem models that use code Defrost test (SW2)
RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC
Other Rheem Heat Pump codes
All Rheem Heat Pump error codes →
Rheem code Defrost test (SW2): homeowner questions
What does Rheem code Defrost test (SW2) mean?
Forced defrost test. With the unit running in heat-pump mode, pressing the SW2 pushbutton forces a defrost that runs until the termination temperature is reached or 14 minutes pass. Pressing SW2 again ends the test. If the unit goes into and out of defrost…
Is it safe to keep using my heat pump with code Defrost test (SW2)?
Usually yes. Code Defrost test (SW2) is normally minor, but if it keeps coming back have it checked.
Can I reset Rheem code Defrost test (SW2) myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code Defrost test (SW2) comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code Defrost test (SW2) near me?
Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Rheem PRL-JEC Installation Instructions, 8.4-8.5 Defrost Test Mode. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.