Rheem Error Code 68: No blower communication (NO BLWR COMM) (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code 68 on a furnace means: No blower communication (NO BLWR COMM). It is also called Rheem diagnostic code 68.

Critical severityFurnaceRGPE/RGLE

Homeowner? What Rheem code 68 means for you

Stop and call Your furnace is reporting: No blower communication (NO BLWR COMM). This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code 68 mean?

IFC cannot communicate with the ECM blower motor. Thermostat also shows Call For Service / CHECK FURNACE to the homeowner.

Applies to: RGPE/RGLE 2-stage 80+

Common causes of Rheem code 68

  • Loose/broken IFC-to-ECM communication wiring
  • No power to the motor
  • Failed ECM motor control
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code 68

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
57Pressure switch stuck open
58Water sense circuit open
59Water sensed / blocked drain
60Blower fault - running (BLWR FLT-RUN)
61Blower fault - blower not running
66Blower overspeed (BLOWER OVRSPEED)
82Supply air sensor fault (SA SENSOR FLT)
93Internal control fault
d1No shared data (NO SHARED DATA)
d4Memory card invalid (MEM CARD INVALD)
d5Card/hardware conflict (CARD-HRD CNFLCT)
d6Blower HP conflict (BLWR HP CNFLCT)

All Rheem Furnace error codes →

Rheem code 68: homeowner questions

What does Rheem code 68 mean?

No blower communication (NO BLWR COMM). IFC cannot communicate with the ECM blower motor. Thermostat also shows Call For Service / CHECK FURNACE to the homeowner.

Is it safe to keep using my furnace with code 68?

No. Code 68 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Rheem code 68 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Rheem code 68 near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: RGPE/RGLE: Table 16 p.49 / Table 20; Fig. 45 p.63. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.