Rheem error code Blinking decimal point on a furnace means: Airflow readout - blinks of right decimal point. It is also called Rheem diagnostic code Blinking decimal point.

Low severityFurnaceRGPE/RGLE

Homeowner? What Rheem code Blinking decimal point means for you

Usually minor Your furnace is reporting: Airflow readout - blinks of right decimal point. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code Blinking decimal point mean?

While the blower runs, the decimal point at the right of the dual display blinks once per 100 CFM of expected airflow (rounded down to the lower hundred). Example: 1049 CFM = 10 blinks, 1051 CFM = 11 blinks. For better resolution use a service tool or the thermostat STATUS menus (BLOWER CFM, which resolves to 10 CFM).

Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code Blinking decimal point

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
68No blower communication (NO BLWR COMM)
82Supply air sensor fault (SA SENSOR FLT)
84Outdoor air sensor fault
93Internal control fault
AFAirflow readout (pushbutton status menu)
Blank thermostat text areaThermostat text area blank - system found OK
CCooling or heat-pump heat (compressor call)
cd / CdDehumidification cooling
CFM LED blinksCFM LED blink count = target airflow
d1No shared data (NO SHARED DATA)
d4Memory card invalid (MEM CARD INVALD)
d5Card/hardware conflict (CARD-HRD CNFLCT)

All Rheem Furnace error codes →

Rheem code Blinking decimal point: homeowner questions

What does Rheem code Blinking decimal point mean?

Airflow readout - blinks of right decimal point. While the blower runs, the decimal point at the right of the dual display blinks once per 100 CFM of expected airflow (rounded down to the lower hundred). Example: 1049 CFM = 10 blinks, 1051 CFM = 11 blinks. For better resolution use a…

Is it safe to keep using my furnace with code Blinking decimal point?

Usually yes. Code Blinking decimal point is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code Blinking decimal point myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code Blinking decimal point comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code Blinking decimal point near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: RGPE Dual Seven-Segment Diagnostic Display, p.49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977