Rheem Error Code 45: Low pressure switch open – inducer high speed (Furnace)
Rheem error code 45 on a furnace means: Low pressure switch open - inducer high speed. It is also called Rheem diagnostic code 45.
Homeowner? What Rheem code 45 means for you
Call a technician Your furnace is reporting: Low pressure switch open - inducer high speed. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code 45 mean?
Low pressure switch did not close (or opened) with the inducer on high speed. If not closed after 60 seconds of inducer run, a 5-minute soft lockout follows. RGPE/RGLE: Table 16 text LPC OPEN; meaning per 802P - verify on unit. Not stored back-to-back in the RGPE fault buffer.
Applies to: 802P/80MDP (802PA050-150); RGPE/RGLE 2-stage 80+
Common causes of Rheem code 45
- Inducer not running or weak
- Loose, leaking, kinked or water-filled pressure hose
- Blocked vent, improper vent size/length or too many elbows
A technician checks these and 3 other possible causes on site before replacing any part.
Rheem models that use code 45
R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Other Rheem Furnace codes
All Rheem Furnace error codes →
Rheem code 45: homeowner questions
What does Rheem code 45 mean?
Low pressure switch open - inducer high speed. Low pressure switch did not close (or opened) with the inducer on high speed. If not closed after 60 seconds of inducer run, a 5-minute soft lockout follows. RGPE/RGLE: Table 16 text LPC OPEN; meaning per 802P - verify on unit. Not stored…
Is it safe to keep using my furnace with code 45?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rheem code 45 myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code 45 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code 45 near me?
Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blowing cold air All brands · Furnace
- No heat All brands · Furnace
- Short cycling All brands · Furnace
- Blower does not start after burners light Rheem · Furnace
- Burners go out before the heat call ends / short cycling Rheem · Furnace
- Communicating system not found / no communication Rheem · Furnace
- ECM blower does not start on heat Rheem · Furnace
- Furnace no heat - sequence troubleshooting Rheem · Furnace
- Furnace short cycles or does not hold setpoint Rheem · Furnace
- Gas valve does not shut off when heat call ends Rheem · Furnace
- Indoor blower does not start after burners light Rheem · Furnace
- Inducer (draft motor) does not start on heat call Rheem · Furnace
- Inducer does not run / does not run on low speed Rheem · Furnace
- Inducer runs 60 s then shuts off for 5 minutes, or runs continuously Rheem · Furnace
- Inducer runs 60 seconds then off for 5 minutes Rheem · Furnace
- No heat - inducer (IDM) does not start Rheem · Furnace
- No heat - POWER LED off Rheem · Furnace
- Read target airflow from the CFM LED Rheem · Furnace
- Thermostat does not hold room temperature Rheem · Furnace
Source: 802P: 92-24161-146-02, Diagnostics and Fault Codes table, p.40-41, 48, 51; RGPE/RGLE: Table 16 p.49 / Table 20; Fig. 45 p.63. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.