Rheem Error Code cd / Cd: Dehumidification cooling (Furnace)
Rheem error code cd / Cd on a furnace means: Dehumidification cooling. It is also called Rheem diagnostic code cd / Cd.
Homeowner? What Rheem code cd / Cd means for you
Usually minor Your furnace is reporting: Dehumidification cooling. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code cd / Cd mean?
On RGPE/RGLE with the dehumidification feature enabled (DIP SW2-1 ON), the display shows cd or Cd instead of the normal c or C when the humidistat input asks for dehumidification during a cooling call. It means cooling is running at the reduced dehumidification airflow. Normal.
Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces
Rheem models that use code cd / Cd
96MDV115D50ARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Other Rheem Furnace codes
All Rheem Furnace error codes →
Rheem code cd / Cd: homeowner questions
What does Rheem code cd / Cd mean?
Dehumidification cooling. On RGPE/RGLE with the dehumidification feature enabled (DIP SW2-1 ON), the display shows cd or Cd instead of the normal c or C when the humidistat input asks for dehumidification during a cooling call. It means cooling is running at the…
Is it safe to keep using my furnace with code cd / Cd?
Usually yes. Code cd / Cd is normally minor, but if it keeps coming back have it checked.
Can I reset Rheem code cd / Cd myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code cd / Cd comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code cd / Cd near me?
Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: RGPE Dipswitch SW2-1 table (Furnace operation using non-communicating thermostats), p.47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.