Rheem Error Code 57: Pressure switch stuck open (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code 57 on a furnace means: Pressure switch stuck open. It is also called Rheem diagnostic code 57.

High severityFurnaceRheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC) · R95P · RGPE/RGLE

Homeowner? What Rheem code 57 means for you

Call a technician Your furnace is reporting: Pressure switch stuck open. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code 57 mean?

802P and RGPE/RGLE: the high-fire pressure switch (HPC) did not close (or opened) when the inducer ran high speed for high fire. R95P (single pressure switch): pressure switch did not close; after 60 seconds of inducer run the control goes into a 5-minute soft lockout and retries. Not stored back-to-back in the RGPE fault buffer.

Applies to: 802P/80MDP (802PA050-150); R95P (R95PA040-115); RGPE/RGLE 2-stage 80+

Common causes of Rheem code 57

  • Weak inducer or not reaching high speed
  • Hose cracked, disconnected, kinked or water-filled
  • Blocked vent/intake, excess vent length or elbows

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code 57

Show all 21 models

R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSAR802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
26Line and neutral reversed
33Rollout switch (MRLC) open
44Low pressure switch closed (stuck)
45Low pressure switch open - inducer high speed
46Low pressure switch open - inducer low speed
55Pressure switch stuck closed
58Water sense circuit open
59Water sensed / blocked drain
60Blower fault - running (BLWR FLT-RUN)
61Blower fault - blower not running
66Blower overspeed (BLOWER OVRSPEED)
68No blower communication (NO BLWR COMM)

All Rheem Furnace error codes →

Rheem code 57: homeowner questions

What does Rheem code 57 mean?

Pressure switch stuck open. 802P and RGPE/RGLE: the high-fire pressure switch (HPC) did not close (or opened) when the inducer ran high speed for high fire. R95P (single pressure switch): pressure switch did not close; after 60 seconds of inducer run the control…

Is it safe to keep using my furnace with code 57?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Rheem code 57 myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code 57 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code 57 near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: 802P: 92-24161-146-02, Diagnostics and Fault Codes table, p.40, 51; R95P: Diagnostics and Fault Codes table, p.87 (PDF p.91); RGPE/RGLE: Table 16 p.49 / Table 20; Fig. 45 p.63. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.