Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rheem RGLE-10(-)BRMR Error Codes

Updated · by Aurora Star Tech Inc.

Rheem RGLE-10(-)BRMR error codes and diagnostic codes (also listed as (-)GLE-10(-)BRMR, GLE-10). The RGLE-10(-)BRMR is a Rheem furnace in the RGPE/RGLE series.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Rheem RGLE-10(-)BRMR error codes list

CodeMeaningSeverity
2 WK HIST / LIFE HIST menusFurnace user menus - run-time historiesLow
10One-hour lockoutHigh
11Failed ignitionHigh
12Low flame senseMedium
13Flame lostHigh
14Unexpected flameCritical
22Main limit openHigh
23HALC limit open (HALC LIMIT OPEN)High
26Line and neutral reversedHigh
33Rollout switch (MRLC) openCritical
44Low pressure switch closed (stuck)High
45Low pressure switch open - inducer high speedHigh
46Low pressure switch open - inducer low speedHigh
55Pressure switch stuck closedHigh
57Pressure switch stuck openHigh
60Blower fault - running (BLWR FLT-RUN)Medium
66Blower overspeed (BLOWER OVRSPEED)Medium
68No blower communication (NO BLWR COMM)Critical
82Supply air sensor fault (SA SENSOR FLT)Low
Blank thermostat text areaThermostat text area blank - system found OKLow
Blinking decimal pointAirflow readout - blinks of right decimal pointLow
CCooling or heat-pump heat (compressor call)Low
cd / CdDehumidification coolingLow
d1No shared data (NO SHARED DATA)Critical
d5Card/hardware conflict (CARD-HRD CNFLCT)Medium
d6Blower HP conflict (BLWR HP CNFLCT)High
d7Blower manufacturer conflict (BLWR MFG CNFLCT)High
d8Old shared data (OLD SHARED DATA)Medium
dFDefrost in progress (dual fuel)Low
FAULT HISTORY menuFurnace user menu - FAULT HISTORYLow
Fault recall - last 5Power-up replay of the last five faultsLow
FIXED FIRE RATEForced low or high fire test (SETUP menu)Low
FURNACE FOUNDThermostat start-up message - equipment foundLow
HGas heat onLow
h (lowercase)Low-fire gas heat onLow
h flashingCalibrating (CALIBRATE-NO V)Low
HPHeat-pump heat running (dual fuel)Low
Learn buttonLearn button - RX LED rapid blink testLow
rLockout indicatorHigh
RX LED blinkingGreen RX LED - network traffic presentLow
SEARCHINGThermostat start-up message - searchingLow
SETUP menuFurnace user menu - SETUPLow
STAT LED double blinkRed STAT LED - two slow blinks at power-upLow
STATUS 1 menuFurnace user menu - STATUS 1Low
STATUS 2 menuFurnace user menu - STATUS 2Low
Top and bottom bars (right digit)Fault history cleared confirmationLow
UNIT INFO menuFurnace user menu - UNIT INFOLow

Troubleshooting the RGLE-10(-)BRMR

Rheem RGLE-10(-)BRMR specs and setup data

All Rheem Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service