Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rheem Error Code Fault recall mode (TEST + SW2): Review stored faults on the ICC display (Heat Pump)

Updated · by Aurora Star Tech Inc.

Rheem error code Fault recall mode (TEST + SW2) on a heat pump means: Review stored faults on the ICC display. It is also called Rheem diagnostic code Fault recall mode (TEST + SW2).

Low severityHeat PumpRheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

Homeowner? What Rheem code Fault recall mode (TEST + SW2) means for you

Usually minor Your heat pump is reporting: Review stored faults on the ICC display. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code Fault recall mode (TEST + SW2) mean?

Shows the stored fault history on the dual display. Entering and leaving the mode lights the top and bottom segments. Faults scroll automatically, newest first, with the top-right segment lit between them. Up to six faults are kept (max three identical in a row). A 0 means nothing is stored. The mode exits by itself after the last fault.

Applies to: Rheem/Ruud PRL-JEC heat pumps with Comfort Control2 ICC

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code Fault recall mode (TEST + SW2)

RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC

Other Rheem Heat Pump codes

CodeMeaning
dDefrost active
d1No shared data
d3Airflow CFM mismatch
d4Memory card invalid for device
d8Old shared data
Defrost test (SW2)Forced defrost test
Flashing c / C / h / HAnti-short-cycle (3 min) or minimum-run (30 s) timer active
hFirst-stage heat pump heating
H (upper case)Second-stage heat pump heating
L4Locked rotor lockout
L6Open start circuit lockout
L7Open run circuit lockout

All Rheem Heat Pump error codes →

Rheem code Fault recall mode (TEST + SW2): homeowner questions

What does Rheem code Fault recall mode (TEST + SW2) mean?

Review stored faults on the ICC display. Shows the stored fault history on the dual display. Entering and leaving the mode lights the top and bottom segments. Faults scroll automatically, newest first, with the top-right segment lit between them. Up to six faults are kept (max…

Is it safe to keep using my heat pump with code Fault recall mode (TEST + SW2)?

Usually yes. Code Fault recall mode (TEST + SW2) is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code Fault recall mode (TEST + SW2) myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code Fault recall mode (TEST + SW2) comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code Fault recall mode (TEST + SW2) near me?

Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Rheem PRL-JEC Installation Instructions, Comfort Control2 section 12.5, pp.23-24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service