Common causes of annual and start-of-season inspection

  • Carbon or scale in heat exchanger tubes
  • Flame sensor fouled
  • Condensate trap blocked (can cause water backup and nuisance overtemperature trips)
  • Illegible furnace markings

How to fix annual and start-of-season inspection: step by step

  1. Inspect the flue passageways, vent system, and main burners for corrosion or other deterioration.
  2. Check main burner flame appearance at start of season and about halfway through the heating season.
  3. If flames are distorted or there is back pressure, check the vent and inlet air system for blockage.
  4. If there is carbon and scale in the heat exchanger tubes, replace the heat exchanger assembly.
  5. Clean the flame sensor with fine steel wool or a Scotch Bright pad.
  6. Inspect the condensate trap for debris or blockage.
  7. Replace the condensate neutralizer if used.
  8. Clean the furnace markings and replace any illegible or missing ones.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

96V

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

96MDV

96MDV06096MDV07096MDV08596MDV100

Source: Rheem 96V installation manual, p. 107. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977