Rheem Error Code RX LED blinking: Green RX LED – network traffic present (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code RX LED blinking on a furnace means: Green RX LED - network traffic present. It is also called Rheem diagnostic code RX LED blinking.

Low severityFurnaceRGPE/RGLE

Homeowner? What Rheem code RX LED blinking means for you

Usually minor Your furnace is reporting: Green RX LED - network traffic present. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code RX LED blinking mean?

Communicating furnaces have a green RX LED that blinks at random whenever the control receives a message from another device on the network (thermostat, condenser). Random blinking is the normal healthy sign. If nothing blinks for five minutes there is no valid communication; steady-on usually means wires 1 and 2 are swapped. Only active with a communicating thermostat installed.

Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code RX LED blinking

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
h (lowercase)Low-fire gas heat on
h flashingCalibrating (CALIBRATE-NO V)
HPHeat-pump heat running (dual fuel)
Learn buttonLearn button - RX LED rapid blink test
Power LED onPower LED on - control has 24 VAC
rLockout indicator
SEARCHINGThermostat start-up message - searching
SETUP menuFurnace user menu - SETUP
STAT LED double blinkRed STAT LED - two slow blinks at power-up
STATUS 1 menuFurnace user menu - STATUS 1
STATUS 2 menuFurnace user menu - STATUS 2
Status LED steady onStatus LED steady - normal (RGRM/RGTM)

All Rheem Furnace error codes →

Rheem code RX LED blinking: homeowner questions

What does Rheem code RX LED blinking mean?

Green RX LED - network traffic present. Communicating furnaces have a green RX LED that blinks at random whenever the control receives a message from another device on the network (thermostat, condenser). Random blinking is the normal healthy sign. If nothing blinks for five…

Is it safe to keep using my furnace with code RX LED blinking?

Usually yes. Code RX LED blinking is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code RX LED blinking myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code RX LED blinking comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code RX LED blinking near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: RGPE Communications L.E.D.s, p.41-42. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.