Rheem Error Code HP: Heat-pump heat running (dual fuel) (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code HP on a furnace means: Heat-pump heat running (dual fuel). It is also called Rheem diagnostic code HP.

Low severityFurnaceRGPE/RGLE · R96V/96MDV

Homeowner? What Rheem code HP means for you

Usually minor Your furnace is reporting: Heat-pump heat running (dual fuel). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code HP mean?

In a dual-fuel setup (communicating condenser with reversing valve) the furnace display shows HP while the heat pump is providing the heat. Normal. Gas heat takes over below the balance point set at the thermostat.

Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code HP

Show all 22 models

96MDV040B30A96MDV060B30A96MDV070B30A96MDV085C50A96MDV100C50A96MDV115D50AR96VA0401317MSAR96VA0601317MSAR96VA0701317MSAR96VA0851521MSAR96VA1001521MSAR96VA1151524MSARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
Flame LED steady onAmber flame LED steady - normal flame sensed
FrFire rate readout (pushbutton status menu)
FURNACE FOUNDThermostat start-up message - equipment found
HGas heat on
h (lowercase)Low-fire gas heat on
h flashingCalibrating (CALIBRATE-NO V)
Learn buttonLearn button - RX LED rapid blink test
Power LED onPower LED on - control has 24 VAC
rLockout indicator
RX LED blinkingGreen RX LED - network traffic present
SEARCHINGThermostat start-up message - searching
SETUP menuFurnace user menu - SETUP

All Rheem Furnace error codes →

Rheem code HP: homeowner questions

What does Rheem code HP mean?

Heat-pump heat running (dual fuel). In a dual-fuel setup (communicating condenser with reversing valve) the furnace display shows HP while the heat pump is providing the heat. Normal. Gas heat takes over below the balance point set at the thermostat.

Is it safe to keep using my furnace with code HP?

Usually yes. Code HP is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code HP myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code HP comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code HP near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: RGPE Dual-fuel operation in communicating mode, p.56. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.