Carrier Mini-Split: Minimum room height and area for flammable refrigerant
Minimum room height and area for flammable refrigerant on a Carrier mini-split: Room height must be at least 7.3 ft (2.2 m). The minimum room area depends on the refrigerant charge and release height, using the tables for the unit.
Applies to: Indoor units with R-454B refrigerant
How to fix minimum room height and area for flammable refrigerant: step by step
- Check that the room is at least 7.3 ft (2.2 m) high.
- Find the minimum room area from the charge and release height table for the unit.
- Make sure the room area of operation or storage matches the table.
- Keep ventilation openings clear of obstruction.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA
More other tips for mini-split
Source: D5FCFA installation manual, p. 3 and p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.