Carrier Mini-Split: Voltage check at outdoor and indoor units

Updated · by Aurora Star Tech Inc.

Voltage check at outdoor and indoor units on a Carrier mini-split: Measure voltage at the outdoor disconnect, outdoor terminal block and indoor unit during start-up.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Wiring

How to fix voltage check at outdoor and indoor units: step by step

  1. Measure 1(L1) to GND, 2(L2) to GND and 1(L1) to 2(L2) at the outdoor disconnect.
  2. Repeat the same checks at the outdoor unit terminal block.
  3. Measure 1(L1) to 2(L2) and 2(L2) to 3(S) at the outdoor unit.
  4. Repeat the checks at the indoor unit voltage check points and record the readings in the start-up checklist.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Source: Carrier D5FSHA installation manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.