Carrier Mini-Split: Evaporator removal
Evaporator removal on a Carrier mini-split: Remove the panel, water collector and water pump first. The coil temperature sensor T2 is pulled out during this job.
Applies to: D5FSOAH, sizes 06K to 18K
How to fix evaporator removal: step by step
- Remove the panel, water collector and water pump.
- Remove the 2 screws of the pipe clamp board.
- Remove the 2 screws on the left side of the evaporator bracket.
- Remove the 2 screws on the right side of the evaporator.
- Cut the zip tie, pull out the coil temperature sensor (T2) and remove 1 ground screw.
- Remove the evaporator.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FSOAH06XAKD5FSOAH12XAKD5FSOAH18XAK
More other tips for mini-split
Source: D5FSOAH service manual, p. 59-60. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.