Carrier Mini-Split: Inverter module (IPM) continuity check

Updated · by Aurora Star Tech Inc.

Inverter module (IPM) continuity check on a Carrier mini-split: Check the IPM module with a diode-style continuity test on the outdoor board.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FSOAH outdoor unit IPM board

How to fix inverter module (ipm) continuity check: step by step

  1. Turn off the outdoor unit and disconnect the power supply.
  2. Discharge the electrolytic capacitors and confirm all stored energy is removed.
  3. Disassemble the outdoor PCB or the IPM board.
  4. Measure the resistance between P and U, V, W, N, and between U and V, W, N, as shown in the figure.
  5. Compare readings with the IPM resistance table; the table values were not legible in the source.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Models

D5FSOAH06XAKD5FSOAH12XAKD5FSOAH18XAK

Source: Carrier D5FSOAH service manual, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.