Carrier Mini-Split: Inverter module (IPM) continuity check
Inverter module (IPM) continuity check on a Carrier mini-split: Check the IPM module with a diode-style continuity test on the outdoor board.
Applies to: D5FSOAH outdoor unit IPM board
How to fix inverter module (ipm) continuity check: step by step
- Turn off the outdoor unit and disconnect the power supply.
- Discharge the electrolytic capacitors and confirm all stored energy is removed.
- Disassemble the outdoor PCB or the IPM board.
- Measure the resistance between P and U, V, W, N, and between U and V, W, N, as shown in the figure.
- Compare readings with the IPM resistance table; the table values were not legible in the source.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FSOAH06XAKD5FSOAH12XAKD5FSOAH18XAK
Source: Carrier D5FSOAH service manual, p. 34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.