Carrier Mini-Split: Refrigerant leak detected by indoor unit sensor
Refrigerant leak detected by indoor unit sensor on a Carrier mini-split: On units with a refrigerant sensor, a detected leak makes the indoor unit show an error code and buzz. The outdoor compressor stops straight away and the indoor fan keeps running. The sensor life is 15 years.
Applies to: Indoor units with refrigerant sensor, flammable refrigerant (R-454B)
Common causes of refrigerant leak detected by indoor unit sensor
- Refrigerant leak in the refrigerant circuit
How to fix refrigerant leak detected by indoor unit sensor: step by step
- Keep the area open or well ventilated before breaking into the system or doing any hot work.
- Remove all naked flames and ignition sources from the area.
- Find the leak with an electronic detector suitable for flammable refrigerant, or with a bubble/fluorescent leak detection fluid. Never use a halide torch or any naked flame detector.
- If brazing is needed, recover all refrigerant or isolate the leaking section with shut-off valves first.
- Keep a dry powder or CO2 fire extinguisher near the charging area when hot work is done.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA
Source: D5FCFA installation manual, p. 3 and p. 5. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.