Carrier Mini-Split: Outdoor to indoor power and communication wiring

Updated · by Aurora Star Tech Inc.

Outdoor to indoor power and communication wiring on a Carrier mini-split: Power and communication run between the outdoor and indoor units. Stranded copper with 600 V insulation is required. A shielded cable can replace the signal conductors in high EMF areas.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FSFAH 9K to 16K

How to fix outdoor to indoor power and communication wiring: step by step

  1. Size wires per NEC or CEC and local codes, using the MCA and MOCP values from the electrical data table.
  2. Use 14/3 stranded wire with ground, 600 V rated, for power and communication from outdoor to indoor unit.
  3. Connect L1 to terminal 1, N or L2 to terminal 2, and communication to terminal 3; land the green ground wire on the ground terminal.
  4. In high EMF areas with communication problems, use 14/2 stranded shielded wire for terminals 2 and 3 (polarity sensitive). Land the shield on ground at the outdoor unit only.
  5. Keep wires clear of refrigerant tubing, the compressor and moving parts, and tighten every connection.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Models

D5FSFAH09XAKD5FSFAH12XAKD5FSFAH16XAK

More commissioning tips for mini-split

Source: D5FSFAH service manual, p. 10. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.