Carrier Mini-Split: Decommissioning and labeling
Decommissioning and labeling on a Carrier mini-split: Before a unit is decommissioned, the technician must be fully familiar with it. Electrical power must be available for the recovery task.
Applies to: D5FSOAH systems
How to fix decommissioning and labeling: step by step
- Take oil and refrigerant samples before recovery if analysis may be needed.
- Isolate the system electrically and pump it down if possible. If a vacuum is not possible, set up a manifold to recover from several points.
- Place the recovery cylinder on scales before recovery starts. Keep the process supervised by a competent person.
- After decommissioning, label the equipment as emptied of refrigerant, with the date and signature.
- Label equipment that contains flammable refrigerant so it is clearly marked.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FSOAH06XAKD5FSOAH12XAKD5FSOAH18XAK
More other tips for mini-split
Source: Carrier D5FSOAH service manual, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.