Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Mini-Split: Drill the wall penetration

Updated · by Aurora Star Tech Inc.

Drill the wall penetration on a Carrier mini-split: Make a sloped wall hole so the drain and piping leave with proper fall.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Wall penetration for indoor/outdoor piping and drain

How to fix drill the wall penetration: step by step

  1. Avoid wires and plumbing in the wall before drilling.
  2. Drill with a 2.5 in (65 mm) core drill, or a 3.54 in (90 mm) core drill if the gas line is 5/8 in (16 mm) or larger.
  3. Drill with a slight downward angle so the outdoor end is about 0.2-0.275 in (5-7 mm) lower than the indoor end.
  4. Place the protective wall cuff in the hole to protect the edges and help seal it at the end of installation.
  5. Pass the drain hose through the hole so water drains to a safe location.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Source: D5FSOAH installation instructions, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977