Carrier Mini-Split: Drill the wall penetration
Drill the wall penetration on a Carrier mini-split: Make a sloped wall hole so the drain and piping leave with proper fall.
Applies to: Wall penetration for indoor/outdoor piping and drain
How to fix drill the wall penetration: step by step
- Avoid wires and plumbing in the wall before drilling.
- Drill with a 2.5 in (65 mm) core drill, or a 3.54 in (90 mm) core drill if the gas line is 5/8 in (16 mm) or larger.
- Drill with a slight downward angle so the outdoor end is about 0.2-0.275 in (5-7 mm) lower than the indoor end.
- Place the protective wall cuff in the hole to protect the edges and help seal it at the end of installation.
- Pass the drain hose through the hole so water drains to a safe location.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Source: D5FSOAH installation instructions, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.