Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Mini-Split: Change indoor unit from 12K to 9K capacity

Updated · by Aurora Star Tech Inc.

Change indoor unit from 12K to 9K capacity on a Carrier mini-split: Downsizing a 45MBCAQ12XA3 indoor unit from 12K to 9K BTU/h using the ENC1 rotary switch. Other capacities stay at factory setting.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 45MBCAQ12XA3 indoor unit

How to fix change indoor unit from 12k to 9k capacity: step by step

  1. Check that ENC1 is at 0 (the 12K default).
  2. Disconnect power first.
  3. Open the electronic control box and set ENC1 to 2. Close the box.
  4. Restore power. The unit now runs as a 9K.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

More settings shortcuts tips for mini-split

Source: Carrier D5FSCAH/D5FLCAH service manual, p. 14-15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.