Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code EH 0E: Water-level alarm malfunction (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code EH 0E on a mini-split means: Water-level alarm malfunction. It is also called Carrier diagnostic code EH 0E.

Medium severityMini-SplitD5FCFA

Homeowner? What Carrier code EH 0E means for you

Check, then call Your ductless mini-split is reporting: Water-level alarm malfunction. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code EH 0E mean?

If the sampling voltage is not 5 V, the LED shows this failure code.

Applies to: D5FCFAH console ductless system, sizes 18K to 60K

Common causes of Carrier code EH 0E

  • Water-level switch not inserted properly
  • Water-level switch broken
  • Water pump faulty

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code EH 0E

D5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA

Other Carrier Mini-Split codes

CodeMeaning
ECC1Other IDU refrigerant sensor detects leakage (multi-zone)
EH0AIndoor EEPROM error
EH 0AEEPROM malfunction (indoor PCB)
EH0bIndoor PCB to display board communication error
EH 0bIndoor main board and display board communication error
EH0EWater-level alarm malfunction
EH00Indoor EEPROM error
EH 00EEPROM malfunction (indoor PCB)
EH02Zero-crossing signal error
EH03Indoor fan speed out of range
EH 03Fan speed out of control (indoor)
EH 06Indoor PCB and display board communication error

All Carrier Mini-Split error codes →

Carrier code EH 0E: homeowner questions

What does Carrier code EH 0E mean?

Water-level alarm malfunction. If the sampling voltage is not 5 V, the LED shows this failure code.

Is it safe to keep using my ductless mini-split with code EH 0E?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code EH 0E myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code EH 0E comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code EH 0E near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FCFAH service manual, p. 41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977