Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code FHCC: Refrigerant sensor error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code FHCC on a heat pump means: Refrigerant sensor error. It is also called Carrier diagnostic code FHCC.

High severityHeat PumpD5FUHA

Homeowner? What Carrier code FHCC means for you

Call a technician Your heat pump is reporting: Refrigerant sensor error. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code FHCC mean?

Refrigerant sensor fault.

Applies to: D5FUHA indoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Carrier Heat Pump codes

CodeMeaning
EL 01Indoor and outdoor unit communication error
EL01IDU & ODU communication error
EL 16Communication malfunction between adapter board and outdoor main board
EL16Communication malfunction between adapter board and outdoor main board
FCForced cooling mode
FH CCRefrigerant sensor error
FL 09Mismatch between new and old platforms
FL09Mismatch between the new and old platforms
Forced defrostForced defrost (short the defrost pins)
LC 06Compressor top (IPM) temperature protection
LD1MOC red LED LD1 (sizes 25-60)
LD5MOC green LED LD5 (sizes 25-60)

All Carrier Heat Pump error codes →

Carrier code FHCC: homeowner questions

What does Carrier code FHCC mean?

Refrigerant sensor error. Refrigerant sensor fault.

Is it safe to keep using my heat pump with code FHCC?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code FHCC myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code FHCC comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code FHCC near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FUHA service manual, p. 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service