Carrier Error Code ON: Amber STATUS LED on solid – standby (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code ON on a heat pump means: Amber STATUS LED on solid - standby. It is also called Carrier diagnostic code ON.

Low severityHeat PumpCarrier Infinity 18VS 25VNA8 · Carrier 2-stage 24ANB/25HNB · Carrier single-stage communicating HP

Homeowner? What Carrier code ON means for you

Usually minor Your heat pump is reporting: Amber STATUS LED on solid - standby. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code ON mean?

The amber STATUS LED on the outdoor control board stays lit without flashing. It means the unit has power and is in standby with no call for operation. On the Infinity units it returns to standby about 2 minutes after the last valid communication.

Applies to: Carrier Infinity 25VNA8/24VNA9 variable speed, 24ANB/25HNB two-stage and single-stage communicating outdoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code ON

25HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB96025VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

Other Carrier Heat Pump codes

CodeMeaning
LD1MOC red LED LD1 (sizes 25-60)
LD5MOC green LED LD5 (sizes 25-60)
LED1MOC red LED1 (sizes 25-60)
LED3MOC amber LED3 (sizes 25-60)
LED200MOC red LED (sizes 13, 24B)
LED207MOC amber LED (sizes 13, 24B)
PC 0aQuick maintenance code (outdoor)
PC 0FQuick maintenance code (outdoor)
PC 0LLow ambient temperature protection
PC0LLow ambient temp. protection
PC00ODU IPM module protection
PC 00Outdoor IPM module protection

All Carrier Heat Pump error codes →

Carrier code ON: homeowner questions

What does Carrier code ON mean?

Amber STATUS LED on solid - standby. The amber STATUS LED on the outdoor control board stays lit without flashing. It means the unit has power and is in standby with no call for operation. On the Infinity units it returns to standby about 2 minutes after the last valid…

Is it safe to keep using my heat pump with code ON?

Usually yes. Code ON is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code ON myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code ON comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code ON near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier 25VNA8/24VNA9 service manual, Table 6 Fault Code Actions (status rows), p.15-16; Carrier residential A/C and heat pump service manual 24-25, Table 14 Status Codes (single-stage communicating HP), p.50-51; Carrier residential A/C and heat pump service manual 24-25, Table 18 Troubleshooting (2-stage 24ANB/25HNB), p.60-61. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.