Carrier Error Code PC 03: High or low pressure protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code PC 03 on a mini-split means: High or low pressure protection. It is also called Carrier diagnostic code PC 03.

High severityMini-SplitD5FCFA

Homeowner? What Carrier code PC 03 means for you

Call a technician Your ductless mini-split is reporting: High or low pressure protection. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code PC 03 mean?

The outdoor pressure switch shuts the system off when high pressure is above 4.4 MPa or low pressure is below 0.13 MPa. The LED shows the failure code.

Applies to: D5FCFAH console ductless system, sizes 18K to 60K

Common causes of Carrier code PC 03

  • Faulty high or low pressure switch wiring to the main board
  • Faulty high or low pressure protector
  • Outdoor ambient above 50 °C

A technician checks these and 5 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code PC 03

D5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA

Other Carrier Mini-Split codes

CodeMeaning
PC 00Error code PC 00
PC01ODU voltage protection
PC 01Outdoor voltage protection
PC02Compressor top overheat (OLP)
PC 02Error code PC 02
PC03Pressure protection
PC03/PC30/PC31Pressure protection (low or high pressure)
PC04Inverter compressor drive error
PC 04Inverter compressor drive error
PC06Discharge temperature protection
PC 06Error code PC 06
PC08Outdoor over-current protection

All Carrier Mini-Split error codes →

Carrier code PC 03: homeowner questions

What does Carrier code PC 03 mean?

High or low pressure protection. The outdoor pressure switch shuts the system off when high pressure is above 4.4 MPa or low pressure is below 0.13 MPa. The LED shows the failure code.

Is it safe to keep using my ductless mini-split with code PC 03?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code PC 03 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code PC 03 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code PC 03 near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FCFAH service manual, p. 45-46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.