Carrier Error Code FH CC: Refrigerant sensor error (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code FH CC on a mini-split means: Refrigerant sensor error. It is also called Carrier diagnostic code FH CC.

High severityMini-SplitD5FSFA

Homeowner? What Carrier code FH CC means for you

Call a technician Your ductless mini-split is reporting: Refrigerant sensor error. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code FH CC mean?

The indoor unit receives a fault signal from the refrigerant sensor for 10 s, or it gets no feedback from the sensor for 150 s.

Applies to: D5FSFAH

Common causes of Carrier code FH CC

  • Refrigerant sensor fault
  • Sensor wiring or connection fault
  • ENC1 setting incorrect

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code FH CC

D5FSFAH09XAKD5FSFAH12XAKD5FSFAH16XAK

Other Carrier Mini-Split codes

CodeMeaning
FH0CIndoor unit humidity sensor malfunction
FH 0dFault - see outdoor unit
FH 0PAP mode on / no Wi-Fi kit
FH0PWireless module self-test failure
FH07Indoor unit lift panel communication failure / opening and closing failure
FHCCRefrigerant sensor error
FL09Mismatch between the new and old platforms
FL 09Mismatch between new and old platforms
FL14Indoor and outdoor units not compatible
FPLow-temperature heating (8 C mode)
J0Outdoor coil overheat in cooling
J1Indoor coil temperature protection in heating

All Carrier Mini-Split error codes →

Carrier code FH CC: homeowner questions

What does Carrier code FH CC mean?

Refrigerant sensor error. The indoor unit receives a fault signal from the refrigerant sensor for 10 s, or it gets no feedback from the sensor for 150 s.

Is it safe to keep using my ductless mini-split with code FH CC?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code FH CC myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code FH CC comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code FH CC near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FSFAH service manual, p. 44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977