Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code FHCC: Refrigerant sensor error (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code FHCC on a mini-split means: Refrigerant sensor error. It is also called Carrier diagnostic code FHCC.

Medium severityMini-SplitD5FSOA

Homeowner? What Carrier code FHCC means for you

Check, then call Your ductless mini-split is reporting: Refrigerant sensor error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code FHCC mean?

The refrigerant sensor has an error.

Applies to: D5FSOAH

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code FHCC

D5FSOAH06XAKD5FSOAH12XAKD5FSOAH18XAK

Other Carrier Mini-Split codes

CodeMeaning
FdVapor injection outlet sensor fault
FH0CIndoor unit humidity sensor malfunction
FH 0dFault - see outdoor unit
FH 0PAP mode on / no Wi-Fi kit
FH0PWireless module self-test failure
FH07Indoor unit lift panel communication failure / opening and closing failure
FH CCRefrigerant sensor error
FL09Mismatch between the new and old platforms
FL 09Mismatch between new and old platforms
FL14Indoor and outdoor units not compatible
FPLow-temperature heating (8 C mode)
J0Outdoor coil overheat in cooling

All Carrier Mini-Split error codes →

Carrier code FHCC: homeowner questions

What does Carrier code FHCC mean?

Refrigerant sensor error. The refrigerant sensor has an error.

Is it safe to keep using my ductless mini-split with code FHCC?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code FHCC myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code FHCC comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code FHCC near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: D5FSOAH service manual, p. 26, 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977