Carrier Error Code ECC1: Other IDU refrigerant sensor detects leakage (multi-zone) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code ECC1 on a heat pump means: Other IDU refrigerant sensor detects leakage (multi-zone). It is also called Carrier diagnostic code ECC1.

High severityHeat PumpD5FUHA

Homeowner? What Carrier code ECC1 means for you

Call a technician Your heat pump is reporting: Other IDU refrigerant sensor detects leakage (multi-zone). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code ECC1 mean?

In a multi-zone system, a refrigerant sensor on another indoor unit has detected a leak.

Applies to: D5FUHA multi-zone system

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Carrier Heat Pump codes

CodeMeaning
EC 54Outdoor temperature sensor open or short
EC54COMP. discharge temp sensor error
EC 55Quick maintenance code (outdoor)
EC 56Outdoor temperature sensor open or short
EC56IDU coil outlet temp sensor error
EC 57Quick maintenance code (outdoor)
EH 0AEEPROM malfunction (indoor unit)
EH0AIDU EEPROM parameter error
EH 0bIndoor main control board and display board communication error
EH0bIDU main control and display boards communication error
EH0EWater-level alarm malfunction
EH 0EWater-level alarm malfunction

All Carrier Heat Pump error codes →

Carrier code ECC1: homeowner questions

What does Carrier code ECC1 mean?

Other IDU refrigerant sensor detects leakage (multi-zone). In a multi-zone system, a refrigerant sensor on another indoor unit has detected a leak.

Is it safe to keep using my heat pump with code ECC1?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code ECC1 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code ECC1 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code ECC1 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FUHA service manual, p. 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.