Trane Error Code 9 Flashes: Ignitor circuit or neutral-to-common voltage (Furnace)
Trane error code 9 Flashes on a furnace means: Ignitor circuit or neutral-to-common voltage. It is also called Trane diagnostic code 9 Flashes.
Homeowner? What Trane code 9 Flashes means for you
Call a technician Your furnace is reporting: Ignitor circuit or neutral-to-common voltage. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Trane error code 9 Flashes mean?
Ignitor circuit fault, or line N to 24 VAC common voltage is too high (above 2 V). Possible grounding problem.
Applies to: Integrated furnace control
Common causes of Trane code 9 Flashes
- Ignitor circuit fault
- Possible grounding problem
Other Trane Furnace codes
All Trane Furnace error codes →
Trane code 9 Flashes: homeowner questions
What does Trane code 9 Flashes mean?
Ignitor circuit or neutral-to-common voltage. Ignitor circuit fault, or line N to 24 VAC common voltage is too high (above 2 V). Possible grounding problem.
Is it safe to keep using my furnace with code 9 Flashes?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Trane code 9 Flashes myself?
You can try one reset (power off for 30 seconds, then on). If Trane code 9 Flashes comes back, the cause is still there and a licensed technician should check it.
Who can fix Trane code 9 Flashes near me?
Aurora Star Tech Inc. repairs Trane furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
- Cycles on limit (not lockout) All brands · Furnace
- Does not start All brands · Furnace
- Flame burns a few seconds then out All brands · Furnace
- Flame conditions table All brands · Furnace
- Heat exchanger leak All brands · Furnace
- High blower-door ACH50 (>3) All brands · Furnace
- High fuel consumption All brands · Furnace
- High stack temperature All brands · Furnace
- High stack temperature / low efficiency All brands · Furnace
- Indoor blower runs, outdoor unit dead All brands · Furnace
- Limit opens All brands · Furnace
- Locks out — oil but no ignition All brands · Furnace
- Low CO2 (<8 %) All brands · Furnace
- Low draft / blowback All brands · Furnace
- Modulating furnace won't modulate All brands · Furnace
- Negative house pressure, backdrafting, infiltration All brands · Furnace
- No heat All brands · Furnace
- No heat (ignition stage) All brands · Furnace
- Noisy All brands · Furnace
- Noisy registers, drafts, blower overamps/ECM noise, coil freezing All brands · Furnace
- Not running / fault code All brands · Furnace
- Oil + ignition OK but no flame All brands · Furnace
- Oil on floor All brands · Furnace
- Pressure switch open / stuck All brands · Furnace
- Puff-back / delayed ignition All brands · Furnace
- Reduced airflow, hot motor All brands · Furnace
- Reduced pressure, smoky shutdowns, lockouts All brands · Furnace
- Rollout switch tripped All brands · Furnace
- Short cycling All brands · Furnace
- Smoke, soot, odour, pulsation All brands · Furnace
- Starts but locks out — no oil at nozzle All brands · Furnace
- Too little / too much air All brands · Furnace
- Unsatisfactory heat (short cycles / uneven / not enough) All brands · Furnace
- Water flows with furnace off All brands · Furnace
- Abnormal conditions and protection Trane · Furnace
- Adjust gas valve manifold pressure Trane · Furnace
- Air for combustion and ventilation in non-direct vent installs Trane · Furnace
- Airflow adjustment check Trane · Furnace
- Airflow and temperature rise check Trane · Furnace
- Blower door interlock Trane · Furnace
- Bottom return filter rack installation (upflow) Trane · Furnace
- Burner box cover reinstallation Trane · Furnace
- Burner box temperature limit reset Trane · Furnace
- Burner box temperature limit shutdown Trane · Furnace
- Carbon monoxide detectors and signage for Massachusetts side-wall venting Trane · Furnace
- Carbon monoxide spillage test (vent check) Trane · Furnace
- Category IV direct vent classification Trane · Furnace
- Choose combustion air method: confined or unconfined space Trane · Furnace
- Close coupled return below 36 in Trane · Furnace
- Combustion and input check Trane · Furnace
- Condensate drain for horizontal installations Trane · Furnace
- Condensate drain for vertical upflow and downflow installations Trane · Furnace
- Condensate drain freeze protection Trane · Furnace
- Corrosive atmosphere and construction debris warning Trane · Furnace
- Do not light burners manually Trane · Furnace
- Do not use field fabricated venting parts Trane · Furnace
- Downflow filter brackets and horizontal filter location Trane · Furnace
- Downflow furnace on combustible floor (subbase) Trane · Furnace
- Downflow installation on combustible floors Trane · Furnace
- Downward venting Trane · Furnace
- Duct connection and return air Trane · Furnace
- Electrical connections and polarity Trane · Furnace
- Filter clip and rack use by cabinet width Trane · Furnace
- Filter placement for upflow furnace in horizontal configuration Trane · Furnace
- Fit the return air filter Trane · Furnace
- Flexible connectors and vibration Trane · Furnace
- Freeze protection and drain pipe sizing Trane · Furnace
- Freeze protection for vent pipe Trane · Furnace
- Freeze protection for vent pipe in unheated spaces Trane · Furnace
- Furnace in attic or crawl space (horizontal) Trane · Furnace
- Furnace location and clearance check before setting in place Trane · Furnace
- Gas leak testing method Trane · Furnace
- Gas piping installation Trane · Furnace
- Gas supply pressure testing Trane · Furnace
- General venting requirements Trane · Furnace
- Heat anticipator setting Trane · Furnace
- High altitude derate and orifice change Trane · Furnace
- Horizontal installation support and drain Trane · Furnace
- Horizontal vent termination through wall Trane · Furnace
- Horizontal venting through a wall Trane · Furnace
- Install alternate upflow filter clip / bracket kit (KIT09224) Trane · Furnace
- Install filter rack for side return on upflow furnace Trane · Furnace
- Limit switch check at startup Trane · Furnace
- Limit switch check during startup Trane · Furnace
- Location, access and clearance checks Trane · Furnace
- Measure manifold pressure from the burner box Trane · Furnace
- Minimum front and door clearances Trane · Furnace
- Minimum return air temperature Trane · Furnace
- Owner shutdown warnings Trane · Furnace
- Preliminary inspections before lighting Trane · Furnace
- Prime the condensate trap at start-up Trane · Furnace
- Propane gas hazard and gas detector Trane · Furnace
- Propane is heavier than air and odorant can fade Trane · Furnace
- PVC solvent cement joint procedure Trane · Furnace
- Read or clear the last 6 faults (L6F menu) Trane · Furnace
- Reading and clearing fault history - Trane S-Series IFC Trane · Furnace
- Reset after lockout Trane · Furnace
- Reset the control to factory defaults Trane · Furnace
- Residential garage installation Trane · Furnace
- Resize remaining vent when a furnace is removed from a shared vent Trane · Furnace
- Roof venting Trane · Furnace
- Run test mode (furnace) Trane · Furnace
- Set thermostat heat anticipator Trane · Furnace
- Shut off gas supply during failure Trane · Furnace
- Side return filter rack installation (upflow, left or right) Trane · Furnace
- Stainless steel vent fitting installation Trane · Furnace
- Temporary heating during building construction Trane · Furnace
- Turn off power before servicing filters Trane · Furnace
- Twinning furnaces Trane · Furnace
- Two pipe venting configurations (same pressure zone) Trane · Furnace
- Upflow 5 or 6 ton above 1800 CFM needs multiple return openings Trane · Furnace
- Upflow cased coil installation Trane · Furnace
- Upflow furnace with cased coil attachment Trane · Furnace
- Upflow return air openings for high-airflow models Trane · Furnace
- Vent and inlet air connection and pipe support Trane · Furnace
- Vent and inlet terminal spacing Trane · Furnace
- Venting system check before placing an appliance back in service Trane · Furnace
- Venting through a ceiling Trane · Furnace
- Venting through a masonry chimney Trane · Furnace
- Wall vent clearances and shielding Trane · Furnace
- Wiring basis for a one-stage heating system Trane · Furnace
Source: Trane installer's manual (AUH1B040A9241A), p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.