Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EH 0b: Display board to main board communication error (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code EH 0b on a mini-split means: Display board to main board communication error. It is also called Viessmann diagnostic code EH 0b.

Medium severityMini-SplitVitocal IND-F

Homeowner? What Viessmann code EH 0b means for you

Check, then call Your ductless mini-split is reporting: Display board to main board communication error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EH 0b mean?

Communication between the display board and main board has failed. See page 31.

Applies to: Indoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Mini-Split codes

CodeMeaning
EC 73Outdoor DC fan motor zero-speed failure
EEWater-level alarm malfunction
EH/EC/EL/PCSee outdoor unit error information
EH0AIndoor EEPROM error
EH 0AEEPROM parameter error (indoor or outdoor)
EH0bIndoor PCB to display board communication error
EH 0EWater-level alarm malfunction
EH00Indoor EEPROM error
EH 00EEPROM parameter error (indoor or outdoor)
EH 00/EH 0AIndoor unit EEPROM parameter error
EH02Zero-crossing signal error
EH 02Zero-crossing signal detection error

All Viessmann Mini-Split error codes →

Viessmann code EH 0b: homeowner questions

What does Viessmann code EH 0b mean?

Display board to main board communication error. Communication between the display board and main board has failed. See page 31.

Is it safe to keep using my ductless mini-split with code EH 0b?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EH 0b myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EH 0b comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EH 0b near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal IND-F DLFSFBH service manual, p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.