Viessmann Mini-Split: Indoor fan speed out of control

Updated · by Aurora Star Tech Inc.

Indoor fan speed out of control on a Viessmann mini-split: The indoor fan speed stays too low. The unit shuts the fan off and retries. After three failed restarts the unit stops and the LED shows the failure.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Indoor fan, DLFSFBH 12K

Common causes of indoor fan speed out of control

  • Fan speed stays below 300 RPM for 50 seconds

How to fix indoor fan speed out of control: step by step

  1. Check the indoor fan motor and its wiring.
  2. Check that the fan runs freely and is not blocked.
  3. Confirm the fan is getting correct supply and control signals.
  4. After the fault clears, watch that the fan holds speed during operation.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: Viessmann Vitocal IND-F DLFSFBH service manual, p. 8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.