Viessmann Mini-Split: Unit starts and stops frequently
Unit starts and stops frequently on a Viessmann mini-split: Check these points before calling a repair company.
Applies to: Vitocal IND-O DLFSOAH, models 09XAK and 18XAK
Common causes of unit starts and stops frequently
- Too much or too little refrigerant in the system.
- Non-condensable gas or moisture in the system.
- Refrigerant circuit blocked.
- Compressor broken.
- Voltage too high or too low.
How to fix unit starts and stops frequently: step by step
- Check for leaks and recharge the system with refrigerant.
- Evacuate and recharge the system with refrigerant.
- Determine which circuit is blocked and replace the malfunctioning component.
- Replace the compressor.
- Install a voltage regulator to stabilize the supply voltage.
If the unit shows an error code, look it up: Viessmann Mini-Split codes
Source: Vitocal IND-O DLFSOAH owner's manual, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.