Viessmann Mini-Split: Final system checks before handover
Final system checks before handover on a Viessmann mini-split: Check tubing, drain, insulation and the indoor unit functions before leaving the site.
Applies to: Indoor unit installation
How to fix final system checks before handover: step by step
- Conceal the tubing where possible.
- Confirm the drain hose slopes downward along its full length.
- Confirm all tubing and connections are insulated.
- Fasten tubes to the outside wall where possible.
- Seal the hole where cables and tubing pass through the wall.
- Check all remote control buttons work.
- Check the display panel lights work.
- Check the air deflection louver moves correctly.
- Check the drain works.
- Show the customer how to operate, clean the filter, set the louver, and hand over the owner's manual and these instructions.
If the unit shows an error code, look it up: Viessmann Mini-Split codes
Models
DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK
Source: DLFSHC installation instructions, p. 17-18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.