Wire the signal and power cable to the indoor unit on a Viessmann mini-split: The field 14/3 cable feeds power and communication from the outdoor unit to the indoor unit.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLFSHC indoor units

How to fix wire the signal and power cable to the indoor unit: step by step

  1. Size the wires per NEC or CEC and local code, using the MCA and MOCP values on the outdoor unit rating plate or instructions.
  2. Run 14/3 power and communication cable: two AC power wires, one communication wire and one ground wire. Do not use BX cable.
  3. Keep polarity correct between the indoor and outdoor units.
  4. In high EMF areas with communication problems, a 14/2 stranded shielded cable can replace wires 2 and 3, with the shield grounded at the outdoor unit only.
  5. Open the front cover, remove the lower panel and open the wire cover. Unscrew and set aside the cable clamp below the terminal block.
  6. Remove the plastic panel on the lower left at the back of the unit and feed the signal wire through from back to front.
  7. Connect each wire to its matching terminal using a u-lug, and screw it firmly.
  8. Fasten the cable with the clamp, then replace the wire cover and the back panel.
  9. Do not mix up live and ground wires.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Models

DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK

Source: DLFSHC installation instructions, p. 13. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.