Viessmann Mini-Split: Buried refrigerant piping limits

Updated · by Aurora Star Tech Inc.

Buried refrigerant piping limits on a Viessmann mini-split: Do not bury more than 36 in (914 mm) of refrigerant pipe. If any section is buried, it needs a 6 in (152 mm) vertical rise to the outdoor unit valve connections. Excess buried length can let refrigerant migrate to the cold section and cause slugging that may damage the compressor at start-up.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLFSHC refrigerant piping

How to fix buried refrigerant piping limits: step by step

  1. Limit buried refrigerant pipe to 36 in (914 mm) maximum.
  2. If any pipe is buried, provide a 6 in (152 mm) vertical rise to the outdoor valve connections.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Models

DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK

More other tips for mini-split

Source: DLFSHC installation instructions, p. 3. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.