Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EH 00: EEPROM parameter error (indoor or outdoor) (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code EH 00 on a mini-split means: EEPROM parameter error (indoor or outdoor). It is also called Viessmann diagnostic code EH 00.

High severityMini-SplitVitocal IND-F

Homeowner? What Viessmann code EH 00 means for you

Call a technician Your ductless mini-split is reporting: EEPROM parameter error (indoor or outdoor). The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EH 00 mean?

The main chip on the indoor or outdoor PCB is not getting feedback from the EEPROM chip.

Applies to: Indoor and outdoor PCB EEPROM

Common causes of Viessmann code EH 00

  • EEPROM chip or its connection on the indoor or outdoor PCB has failed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Mini-Split codes

CodeMeaning
EH0AIndoor EEPROM error
EH 0AEEPROM parameter error (indoor or outdoor)
EH0bIndoor PCB to display board communication error
EH 0bDisplay board to main board communication error
EH 0EWater-level alarm malfunction
EH00Indoor EEPROM error
EH 00/EH 0AIndoor unit EEPROM parameter error
EH02Zero-crossing signal error
EH 02Zero-crossing signal detection error
EH03Indoor fan speed out of range
EH 03Indoor fan speed out of normal range
EH 3AExternal fan DC bus voltage too low

All Viessmann Mini-Split error codes →

Viessmann code EH 00: homeowner questions

What does Viessmann code EH 00 mean?

EEPROM parameter error (indoor or outdoor). The main chip on the indoor or outdoor PCB is not getting feedback from the EEPROM chip.

Is it safe to keep using my ductless mini-split with code EH 00?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EH 00 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EH 00 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EH 00 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSFBH Service Manual, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977