Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Mini-Split: Electronic control board access, size 36K

Updated · by Aurora Star Tech Inc.

Electronic control board access, size 36K on a Viessmann mini-split: Steps to open the control box and remove the electronic control board and key board on the terminal board.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLCLRC outdoor unit, size 36K (Models 36AAK)

How to fix electronic control board access, size 36k: step by step

  1. Loosen the 4 hooks, then open the electronic control box cover.
  2. Remove the 6 screws on the electronic control board, then turn the board over.
  3. Pull out the connector.
  4. Remove the 4 screws, then remove the electronic control board.
  5. Pull out the connector, remove one screw, then remove the key board subassembly on the terminal board.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: DLCLRC service manual, p. 45-46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977