Viessmann Error Code EC 73: Outdoor DC fan motor zero-speed failure (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC 73 on a mini-split means: Outdoor DC fan motor zero-speed failure. It is also called Viessmann diagnostic code EC 73.

High severityMini-SplitVitocal 100-S · DLCURA

Homeowner? What Viessmann code EC 73 means for you

Call a technician Your ductless mini-split is reporting: Outdoor DC fan motor zero-speed failure. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC 73 mean?

Outdoor DC fan motor reads zero speed.

Applies to: DLCURA 18-60 outdoor unit

Common causes of Viessmann code EC 73

  • Faulty fan motor
  • Fan assembly obstructed or hard to turn
  • Wiring or connection fault

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EC 73

Show all 22 models

36AAK48AAK58AAK80ES(N,L)80ESUDLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABKFEM4FVM4X48***LFVM4X60***LFXM4X48**ALFXM4X60**AL

Other Viessmann Mini-Split codes

CodeMeaning
EC57Refrigerant pipe sensor fault
EC 57Refrigerant pipe temperature sensor fault
EC71Outdoor fan motor over-current
EC 71Outdoor DC fan motor overcurrent failure
EC72Outdoor fan motor phase loss
EC 72Outdoor DC fan motor lack of phase failure
EEWater-level alarm malfunction
EH/EC/EL/PCSee outdoor unit error information
EH0AIndoor EEPROM error
EH 0AEEPROM parameter error (indoor or outdoor)
EH0bIndoor PCB to display board communication error
EH 0bDisplay board to main board communication error

All Viessmann Mini-Split error codes →

Viessmann code EC 73: homeowner questions

What does Viessmann code EC 73 mean?

Outdoor DC fan motor zero-speed failure. Outdoor DC fan motor reads zero speed.

Is it safe to keep using my ductless mini-split with code EC 73?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EC 73 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC 73 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC 73 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann DLCURA service manual, p. 27 (diagnosis p. 27; fan motor check p. 28). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.