Install interconnecting piping and wiring to the indoor unit on a Viessmann mini-split: Run the lines from the outdoor unit to the indoor unit, hang the indoor unit, then make the flare connections.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Indoor unit installation

How to fix install interconnecting piping and wiring to the indoor unit: step by step

  1. Run the interconnecting piping and wiring from the outdoor unit through the wall hole to the indoor unit.
  2. Lift the indoor unit onto the mounting plate, hook the upper claw, then push the lower part up until it is fully hooked.
  3. Open the front cover, remove the field terminal block cover, and connect the outdoor wiring per the connection diagram.
  4. Replace the terminal cover and close the front cover.
  5. Cut the pipe square at 90 degrees with a pipe cutter and remove all burrs without letting any fall inside the tube.
  6. Remove the service connection if fitted, then fit the correct flare nut to the tubing.
  7. Oil the flare seat lightly, align the pipe centre with the valve, and tighten the flare nut to the torque in the torque table.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Models

DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK

Source: DLFSHC installation instructions, p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.