Viessmann Mini-Split: Remove the evaporator and coil temperature sensor T2
Remove the evaporator and coil temperature sensor T2 on a Viessmann mini-split: Remove the panel, water collector and water pump first. T2 is the coil temperature sensor. Its ribbon must be cut and the ground screw removed.
Applies to: DLFSOAH indoor units 09XAK and 18XAK
How to fix remove the evaporator and coil temperature sensor t2: step by step
- Remove the panel, water collector and water pump.
- Remove the 2 screws of the pipe clamp board.
- Remove the 2 screws on the left side of the evaporator bracket.
- Remove the 2 screws on the right side of the evaporator.
- Cut the ribbon, pull out coil temperature sensor T2 and remove the 1 ground screw.
- Remove the evaporator.
If the unit shows an error code, look it up: Viessmann Mini-Split codes
Source: DLFSOAH Service Manual, p. 50-51. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.