Viessmann Mini-Split: Enter and exit Inquiry Mode
Enter and exit Inquiry Mode on a Viessmann mini-split: Inquiry Mode shows live sensor and operating values on the indoor display. Codes 0 to 30 are read with the UP and DOWN arrows. Each code shows on the indoor display about 1 second after access. Press OK to send.
Applies to: Remote controller and indoor display
How to fix enter and exit inquiry mode: step by step
- Press and hold the On/Off and Fan buttons together for 8 seconds to enter Inquiry Mode.
- Press UP or DOWN to step through codes 0 to 30.
- Press and hold On/Off and Fan together for 2 seconds to exit.
- If no button is pressed, the remote stays in Inquiry Mode for 1 minute.
If the unit shows an error code, look it up: Viessmann Mini-Split codes
Models
DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK
More service & test modes tips for mini-split
Source: DLFSHC service manual, p. 13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.