Viessmann Mini-Split: Remove the evaporator subassembly

Updated · by Aurora Star Tech Inc.

Remove the evaporator subassembly on a Viessmann mini-split: The front panel, panel frame and both air outlet frame assemblies must be removed first.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLFSFBH indoor floor console unit, 12K

How to fix remove the evaporator subassembly: step by step

  1. Remove the front panel, panel frame subassembly, upper air outlet frame and lower air outlet frame.
  2. Remove the 1 screw and take out the auxiliary water pan.
  3. Remove the one screw used for the ground connection.
  4. Pull out the coil temperature sensor.
  5. Remove the evaporator subassembly.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: Vitocal IND-F DLFSFBH service manual, p. 46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.