Weil-McLain Error Code Hb: PP three times and Tw_out under 44.6 F (Heat Pump)
Weil-McLain error code Hb on a heat pump means: PP three times and Tw_out under 44.6 F. It is also called Weil-McLain diagnostic code Hb.
Homeowner? What Weil-McLain code Hb means for you
Stop and call Your heat pump is reporting: PP three times and Tw_out under 44.6 F. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Weil-McLain error code Hb mean?
PP happened three times with outlet water below 44.6 F.
Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)
Common causes of Weil-McLain code Hb
- Same as PP
Weil-McLain models that use code Hb
Other Weil-McLain Heat Pump codes
All Weil-McLain Heat Pump error codes →
Weil-McLain code Hb: homeowner questions
What does Weil-McLain code Hb mean?
PP three times and Tw_out under 44.6 F. PP happened three times with outlet water below 44.6 F.
Is it safe to keep using my heat pump with code Hb?
No. Code Hb is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.
Can I reset Weil-McLain code Hb myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Weil-McLain code Hb near me?
Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- Blank display at first start-up Weil-McLain · Heat Pump
- Does not switch from DHW back to heat right away Weil-McLain · Heat Pump
- Does not switch from heat to DHW right away Weil-McLain · Heat Pump
- Not enough heat in very cold weather Weil-McLain · Heat Pump
- Pressure relief valve drips Weil-McLain · Heat Pump
- Pressure relief valve opens Weil-McLain · Heat Pump
- Pump noisy (cavitation) Weil-McLain · Heat Pump
- Unit on but not heating or cooling as expected Weil-McLain · Heat Pump
Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.3 Error codes, p.57. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.