Weil-McLain Error Code Hb: PP three times and Tw_out under 44.6 F (Heat Pump)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code Hb on a heat pump means: PP three times and Tw_out under 44.6 F. It is also called Weil-McLain diagnostic code Hb.

Critical severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code Hb means for you

Stop and call Your heat pump is reporting: PP three times and Tw_out under 44.6 F. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code Hb mean?

PP happened three times with outlet water below 44.6 F.

Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)

Common causes of Weil-McLain code Hb

  • Same as PP
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code Hb

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
H5Room temperature sensor (Ta) fault
H6DC fan motor fault
H7AC supply voltage protection
H8Pressure sensor fault
H9Zone 2 water temperature sensor (Tw2) fault
HAWater outlet temperature sensor (Tw_out) fault
HECommunication fault with Ta / room thermostat transfer board
HFOutdoor unit EEPROM fault
HHH6 fan fault 10 times in 120 minutes
HPLow pressure in cooling, 3 times in an hour
L0DC compressor inverter module fault
L1DC bus low voltage protection

All Weil-McLain Heat Pump error codes →

Weil-McLain code Hb: homeowner questions

What does Weil-McLain code Hb mean?

PP three times and Tw_out under 44.6 F. PP happened three times with outlet water below 44.6 F.

Is it safe to keep using my heat pump with code Hb?

No. Code Hb is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.

Can I reset Weil-McLain code Hb myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Weil-McLain code Hb near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.3 Error codes, p.57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977