Weil-McLain Error Code H0: Communication fault between indoor and outdoor unit (Heat Pump)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code H0 on a heat pump means: Communication fault between indoor and outdoor unit. It is also called Weil-McLain diagnostic code H0.

High severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code H0 means for you

Call a technician Your heat pump is reporting: Communication fault between indoor and outdoor unit. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code H0 mean?

The indoor unit (hydro-box) main board and the outdoor main board (PCB B) are not talking to each other.

Applies to: ECO HP 41/48/55 MBH indoor and outdoor units

Common causes of Weil-McLain code H0

  • Communication wire between the units not connected or loose
  • Wires in the wrong order
  • Electrical noise from big loads nearby (elevators, large transformers)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code H0

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
EACompressor discharge temperature sensor (Tp) fault
EbSolar panel temperature sensor (Tsolar) fault
EdWater inlet temperature sensor (Tw_in) fault
EEHydro-box PCB EEPROM fault
ELCommunication fault between hydraulic module and MH-kit
F1DC bus low voltage
H1Communication fault between main board and inverter board (outdoor)
H2Refrigerant temperature sensor at plate HX outlet (heating) (T2) fault
H3Refrigerant temperature sensor at plate HX inlet (heating) (T2B) fault
H4L0/L1 protection happened 3 times in an hour
H5Room temperature sensor (Ta) fault
H6DC fan motor fault

All Weil-McLain Heat Pump error codes →

Weil-McLain code H0: homeowner questions

What does Weil-McLain code H0 mean?

Communication fault between indoor and outdoor unit. The indoor unit (hydro-box) main board and the outdoor main board (PCB B) are not talking to each other.

Is it safe to keep using my heat pump with code H0?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code H0 myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code H0 comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code H0 near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.35; Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.3 Error codes, p.56. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.