Updated · by Aurora Star Tech Inc.

Weil-McLain error code L2 on a heat pump means: DC bus high voltage protection. It is also called Weil-McLain diagnostic code L2.

High severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code L2 means for you

Call a technician Your heat pump is reporting: DC bus high voltage protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code L2 mean?

The inverter saw high DC bus voltage.

Applies to: ECO HP 41/48/55 MBH outdoor unit (ODU)

Common causes of Weil-McLain code L2

  • System pressure problem
  • Compressor winding fault
  • U-V-W leads loose or in the wrong order

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code L2

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
HECommunication fault with Ta / room thermostat transfer board
HFOutdoor unit EEPROM fault
HHH6 fan fault 10 times in 120 minutes
HPLow pressure in cooling, 3 times in an hour
L0DC compressor inverter module fault
L1DC bus low voltage protection
L4MCE fault
L5Zero speed protection
L7Phase loss protection
L8Compressor speed changed more than 15 Hz in one second
L9Compressor speed off target by more than 15 Hz
P0Low pressure protection

All Weil-McLain Heat Pump error codes →

Weil-McLain code L2: homeowner questions

What does Weil-McLain code L2 mean?

DC bus high voltage protection. The inverter saw high DC bus voltage.

Is it safe to keep using my heat pump with code L2?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code L2 myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code L2 comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code L2 near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.38. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977