Updated · by Aurora Star Tech Inc.

Weil-McLain error code P3 on a heat pump means: AC current protection. It is also called Weil-McLain diagnostic code P3.

High severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code P3 means for you

Call a technician Your heat pump is reporting: AC current protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code P3 mean?

Current draw on the supply went over the limit.

Applies to: ECO HP 41/48/55 MBH outdoor unit (ODU)

Common causes of Weil-McLain code P3

  • Same causes as P1 (high pressure)
  • Supply voltage too low
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code P3

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
L5Zero speed protection
L7Phase loss protection
L8Compressor speed changed more than 15 Hz in one second
L9Compressor speed off target by more than 15 Hz
P0Low pressure protection
P1High pressure protection
P4Compressor discharge temperature too high
P5Water temperature difference too high (Tw_out - Tw_in)
P6Inverter module protection
PbAnti-freeze mode
PdOutdoor coil (T3) temperature too high
PPTw_out - Tw_in reading not normal

All Weil-McLain Heat Pump error codes →

Weil-McLain code P3: homeowner questions

What does Weil-McLain code P3 mean?

AC current protection. Current draw on the supply went over the limit.

Is it safe to keep using my heat pump with code P3?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code P3 myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code P3 comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code P3 near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.