Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Error Code HE: Communication fault with Ta / room thermostat transfer board (Heat Pump)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code HE on a heat pump means: Communication fault with Ta / room thermostat transfer board. It is also called Weil-McLain diagnostic code HE.

Low severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code HE means for you

Usually minor Your heat pump is reporting: Communication fault with Ta / room thermostat transfer board. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code HE mean?

RT/Ta PCB is turned on in the user interface, but the thermostat transfer board is missing or not talking to the main board.

Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)

Common causes of Weil-McLain code HE

  • Transfer board not installed while RT/Ta PCB is set to valid
  • Communication wire between transfer board and main board loose
  • Electrical or magnetic interference
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code HE

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
H6DC fan motor fault
H7AC supply voltage protection
H8Pressure sensor fault
H9Zone 2 water temperature sensor (Tw2) fault
HAWater outlet temperature sensor (Tw_out) fault
HbPP three times and Tw_out under 44.6 F
HFOutdoor unit EEPROM fault
HHH6 fan fault 10 times in 120 minutes
HPLow pressure in cooling, 3 times in an hour
L0DC compressor inverter module fault
L1DC bus low voltage protection
L2DC bus high voltage protection

All Weil-McLain Heat Pump error codes →

Weil-McLain code HE: homeowner questions

What does Weil-McLain code HE mean?

Communication fault with Ta / room thermostat transfer board. RT/Ta PCB is turned on in the user interface, but the thermostat transfer board is missing or not talking to the main board.

Is it safe to keep using my heat pump with code HE?

Usually yes. Code HE is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code HE myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code HE comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code HE near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.3 Error codes, p.57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977