Viessmann Error Code EL 16: Adapter board to outdoor main board communication malfunction (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code EL 16 on a mini-split means: Adapter board to outdoor main board communication malfunction. It is also called Viessmann diagnostic code EL 16.

Medium severityMini-SplitVitocal 100-S · DLCURA

Homeowner? What Viessmann code EL 16 means for you

Check, then call Your ductless mini-split is reporting: Adapter board to outdoor main board communication malfunction. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EL 16 mean?

Communication fault between the adapter board and the outdoor main board.

Applies to: DLCURA 18-60 outdoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EL 16

Show all 22 models

36AAK48AAK58AAK80ES(N,L)80ESUDLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABKFEM4FVM4X48***LFVM4X60***LFXM4X48**ALFXM4X60**AL

Other Viessmann Mini-Split codes

CodeMeaning
EH b3Wired controller to indoor unit communication error
EH bAExternal fan module to indoor unit communication fault
EL0CRefrigerant leak detected
EL 0CRefrigerant leakage detection
EL01Indoor / outdoor communication error
EL 01Indoor / outdoor communication error
F0Current overload protection
F1Outdoor ambient sensor (T4) fault
F2Condenser coil sensor (T3) fault
F3Discharge sensor (T5) fault
F4Outdoor EEPROM error
F5Outdoor fan speed out of control

All Viessmann Mini-Split error codes →

Viessmann code EL 16: homeowner questions

What does Viessmann code EL 16 mean?

Adapter board to outdoor main board communication malfunction. Communication fault between the adapter board and the outdoor main board.

Is it safe to keep using my ductless mini-split with code EL 16?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EL 16 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EL 16 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EL 16 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann DLCURA service manual, p. 25 (table p. 49). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.