Viessmann Error Code EL0C: Refrigerant leak detected (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code EL0C on a mini-split means: Refrigerant leak detected. It is also called Viessmann diagnostic code EL0C.

High severityMini-SplitViessmann DLFSHB high wall indoor

Homeowner? What Viessmann code EL0C means for you

Call a technician Your ductless mini-split is reporting: Refrigerant leak detected. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EL0C mean?

The indoor coil (T2) did not drop at least 2 C below its start value within 5 minutes of compressor start, 3 times. Display shows EC and the unit stops.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Common causes of Viessmann code EL0C

  • Low charge / leak
  • T2 sensor loose or bad
  • Blockage

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EL0C

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Viessmann Mini-Split codes

CodeMeaning
EH02Zero-crossing signal error
EH03Indoor fan speed out of range
EH30Indoor external fan low voltage
EH31Indoor external fan over voltage
Eh60Room sensor (T1) fault
Eh61Indoor coil sensor (T2) fault
EL01Indoor / outdoor communication error
F0Current overload protection
F1Outdoor ambient sensor (T4) fault
F2Condenser coil sensor (T3) fault
F3Discharge sensor (T5) fault
F4Outdoor EEPROM error

All Viessmann Mini-Split error codes →

Viessmann code EL0C: homeowner questions

What does Viessmann code EL0C mean?

Refrigerant leak detected. The indoor coil (T2) did not drop at least 2 C below its start value within 5 minutes of compressor start, 3 times. Display shows EC and the unit stops.

Is it safe to keep using my ductless mini-split with code EL0C?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EL0C myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EL0C comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EL0C near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17, p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.